When your applications demand more than a standard balance, the
new Ohaus Voyager® Pro analytical balance is up to the task. Voyager Pro´s Advanced
Applications simplify even the most complex laboratory measurements.
Whether it’s determining the difference between initial and
residual weights or calculating the density of solids and liquids,
Voyager Pro eliminates the need for time consuming manual calculations
and data logging.
Advanced in applications but not in operation. With Voyager
Pro´s dot matrix
display and intuitive user interface, balance setup and use is effortless. For
superior weighing performance, Voyager Pro´s AutoCal™ feature automatically
calibrates the balance when it senses a temperature change sufficient enough
to affect weighing accuracy.
The Voyager Pro also includes an ergonomic leveling system; cursor keys for menu
navigation and balance setup; one function per key; auxiliary port; menu and
calibration lock-out switch; factory reset option; spill gutter; removable draft
shield doors.
Standard Features on both the Voyager Pro Analytical
and the Voyager Pro Precision
- AutoCal automatic internal calibration system
- The most advanced application modes in the industry, including:
- Statistics
- Formulation
- Differential Weighing
- Statistical Quality Control (SQC)
- Density Determination
- Pipette Calibration
- Standard application modes including:
- Percent Weighing
- Animal Weighing
- Check Weighing
- Filling
- Parts Counting
- Gross/Net/Tare Weighing
- Applications library to store and quickly recall past procedures
- Brilliant backlit high resolution dot matrix display with simple
navigation windows and menus to guide you through balance functions
- User selectable GLP/GMP outputs via RS232 to meet traceability
requirements
- User selectable filter, stability indicator and auto-zero tracking
for use in difficult environments
- Five operating languages--English, Spanish, French, German,
Italian
- Weigh-below hook for below-balance weighing applications
- Protective in-use cover and security bracket
- 2 year Ohaus warranty
- Click here for additional features
- Click here for more information
about Voyager Pro's applications
- Click here for more about the Voyager
Pro's weighing modes
Model Number: |
VP64CN |
VP114CN |
VP214CN |
VP214DCN* |
Price |
$2333.60 |
$2480.80 |
$2774.40 |
$2525.60 |
Capacity |
62 g |
110 g |
210 g |
100/210 g |
Readability |
0.1 mg |
0.1 mg |
0.1 mg |
0.1 / 1 mg |
Weighing Modes |
gram, milligram,
ounce, troy ounce, carat, pennyweight, Hong Kong tael, Singapore
tael, Taiwan tael, mommes, grain, tical, Newton, custom |
| Application Modes |
Statistics, Formulation, Differential
Weighing, SQC, Density Determination, Pipette Calibration, Parts Counting,.
Animal Weighing, Check Weighing, Percent Weighing, Filling, Gross-Net-Tare
Weighing |
| Features |
Applications Library, RS232 Port, Auxiliary
Display Port, GLP Protocol, Selectable Operations Language, Selectable
Displayed Information Settings, Selectable Environmental Settings,
Selectable Auto-Print Settings, Integral Weigh Below Hook, Contrast & Brightness
Control, Protective In-Use Cover |
Repeatability (std dev) (mg) |
0.1 mg |
0.1 / 0.5 mg |
Linearity (mg) |
± 0.2 mg |
±0.2 / 0.5 mg |
| Tare Range |
Full capacity by subtraction |
| Stabilization Time |
4 seconds |
| Operating Temperature Range |
50° to 104°F (10° to 40°C
) |
Display |
LCD Dot Matrix with Back light -- 240
x 128 pixels |
Power Requirements |
100-120 V AC, 220-240 V AC, 50/60 Hz |
Pan Size |
3.5" (9 cm) dia |
Dimensions
(W x H x D) |
8.3" x 13.8" x 13.8" (21
x 35 x 35 cm) |
| Net Weight |
13.2 lb (6 kg) |
*moveable Fine Range™
| Key
Features |
- Superior Draftshield
A large 3-door draftshield is standard on all Voyager Pro Analytical
and Voyager Pro Precision balances with a 0.1/1 mg readability. The
draftshield design provides optimum draft protection from wind currents
for superior balance stability and reproducibility even in challenging
environments. the large chamber can accommodate larger vessels and
the removable side doors make it easy to clean
- Automatic Calibration
Voyager Pro's standard AutoCal™ calibration feature automatically
calibrates the balance when it senses a temperature change sufficient
enough to affect weighing accuracy. This feature assures accuracy while
saving operational time.
- Protective Cover
Voyager Pro's standard in-use cover is replaceable and protects the display
from harsh environments or spills that can ruin the balance.
- Large Brilliant Display
Voyager Pro's high-resolution dot matrix display with backlight enhances
viewing in any environment and has adjustable contrast and brightness
controls. The display illustrates the weighing results with large numeric
indicators and features user definable text fields to illustrate only
the information you want! The display also illustrates secondary units,
time and date.
- Communication Port with GLP/GMP
Data Output
The standard RS232 communication port offers connectivity and it's GLP/GMP
data output capability prints time, date, balance, project, user ID,
calibration information and weighing information. Simply connect your
Voyager Pro to the optional Ohaus SF42 accessory printer and full traceability
of weighing procedures is achieved without the need for sophisticated,
expensive peripherals.
- Innovative Software
Voyager Pro's innovative user interface combines a dot matrix display
with scroll down menus, software prompts and 5 operating languages.
Balance setup and use is made simple and easy to follow with no training
required. The three application-specific soft-keys allow direct access
to features such as calibration, units, sample size and reference information
at the touch of a button. An applications library stores and quickly
recalls past procedures eliminating the need to re-establish application
parameters.
|
| Voyager
Pro Applications |
Advanced in applications but not in operation. With Voyager Pro's dot matrix
display and innovative user interface, balance setup and use is effortless.
For superior weighing performance, Voyager Pro's AutoCal™ feature
automatically calibrates the balance when it senses a temperature change
sufficient enough to affect weighing accuracy.
Statistical Quality Control (SQC)
The SQC feature is extremely useful during various types
of process filling operations when it is desired to monitor
and control the process to eliminate under and over filling.
Provisions are made in the balance to accommodate the weight
of various packaging methods. During operation, parameters
of the packaged product are set into the balance such as
packaging weight, acceptable weight limits and non-acceptable
weight limits of the product.
These weight limits are identified as +T1, +T2, NOMINAL
and -T1, -T2. As samples are weighed and stored in the
balance, a trend analysis is developed and displayed on
the balance. Up to 25 samples in a batch with up to 10
batches are visible on a trend screen for quality control
purposes. Each batch of samples is shown on the display
which indicates the maximum/minimum standard deviation
and mean values for each batch. An ongoing examination
of the relative deviation of the samples along with other
statistical data can be viewed and is stored. By observing
the results of the VIEW TRACE screen, you can effectively
monitor the filling process operation.
Statistics
Statistics are used when it is desired to compare a number
of samples along with other statistical data. A minimum
of three samples are required in this program. Statistics
contains menu options which include: number of samples,
maximum, minimum, difference, sum, mean, standard deviation,
relative deviation, auto sample, and auto print. Weighing,
Animal Weighing, Check Weighing and Filling application
modes can also be linked to the Statistics mode to provide
statistical data.
Differential Weighing
Differential weighing stores tare and weight values so
samples can be dried or processed and the difference in
weight be calculated. Up to 80 samples can be stored. The
balance has the capability to work with one or two different
containers or no container at all.
Pipette Calibration
Pipette calibration checks the accuracy and precision
values of pipettes by weight analysis. An analytical balance
is recommended for maximum accuracy. The balance is capable
of recording data from 3 to 30 samples of each pipette
tested. The density table for water is included and if
liquid is used for pipette calibration, Voyager Pro will
accept the alternate liquid's density in g/cc at current
room temperature. Since all calculations are made within
the balance, it is also required that you know the atmospheric
pressure which has to be entered.
Density
Four methods of density determinations can be made with
the Voyager Pro balance. These are:
- Solids more dense than water
- Solids less dense than water
- Liquid density
- Porous material (impregnated with oil)
An accessory density determination kit is designed to
be used with Ohaus Voyager Pro balances. A built-in reference
density table for water at temperatures between 10° C
and 30°C is included in the balance software. When
making density measurements, the material should weigh
at least 10.0 mg on an analytical balance and 100 mg on
a precision balance.
Formulation
Formulations can be named and have from 2 to 10 components
specified. Once named, they may be recalled and used at
any time. Each component of a given formulation can be
specified as to its weight or percentage. Each element
of a formulation is shown on a dual bar graph as a percentage
and displays the desired weight. Thus, each component may
be placed on the pan until 100% is indicated.
Weighing
Modes
Application
Modes
- Differential Weighing
- Formulation
- Statistics
- Density Determination
- SQC
- Pipette Calibration
- Animal Weighing
- Parts Counting
- Percent Weighing
- Check Weighing
- Filling
- Gross/Net/Tare Weighing
|
Weighing Modes
- Milligrams
- Grams
- Kilograms
- Pounds
- Ounces
- Carats
- Troy Ounces
- Newtons
|
- Grains
- Mommes
- Taels (3)
- Ticals
- Pennyweights
- User Programmable Custom Unit
|
|
| Feature |
Advantage |
Benefit |
Advanced Weighing Applications Standard:
- Pipette Calibration
- Statistics
- SQC
- Formulation
|
Integration of applications into
Voyager Pro as a complete solution |
Provides simplified, automated
measurement analysis saving time and cost on
additional equipment |
| AutoCal™ Internal Calibration Standard
on all modes |
Voyager Pro models self-calibrate
when they sense temperature changes |
Ensures accurate measurements
in all conditions |
Intuitive Keypad Layout
- Simple 2-butoon operation for basic weighing
- Soft key dynamic mapping for advanced
operation
|
Easy to use. Accessible and repeatable
operation. Soft keys provide measurement flexibility. |
No training required to operate
balance. Saves time by allowing each mode to
have dedicated keys. |
| Brilliant High-Resolution Graphic Display |
High contrast and large size
are easy to see and easy to read
Provides complete information. Enough space
to hold pertinent measurement information |
Allows easy viewing in all
lighting conditions; production lines, under
vent hoods, etc. Less chance for human error
and creates less strain on eyes.
Eliminates uncertainty and potential for
user errors. Display provides through measurement
details, reduces amount of manual calculations |
| All Voyager Pro balances are NTEP approved
Legal for Trade (USA only) |
Balances can be used in either
standard applications or legal for trade. |
Flexibility in applications,
customers not forced into single path with
purchase. Approved status further verifies
instrument fidelity and quality. |
|
|
|