PMA Series | FC
Series | Specs | Accessories
Sartorius
PMA-7500 Series Explosion Proof Paint Mixing Scales
Sartorius PMA7500 Paint-Mixing Scales meet all requirements when
it comes to mixing paints fast, reliably and accurately under tough
ambient conditions. All components of the compact and rugged housings
are resistant to solvents. The round stainless steel weighing pan
is easy to clean and features a wrap-around design. This means
it has an overlapping rim that protects the weighing system all-around
against dirt and spillage. Moreover, the scale is protected against
overloads. Whether you operate the display and control unit with
thinner-stained gloves or paint-blotched fingers, you won’t
have to worry about damaging the keypad overlay. Its advanced,
easy to-clean design protects the key labeling from obliteration
by paint jobs.
- Approved for Class 1, Division 1, Groups (CD Power Supply must
be run to safe area)
- Corrects non-conforming mixes (optional recalculation feature)
- Especially suited for mixing in tough ambient conditions
- Housing parts resistant to solvents
- Easy-to-clean keypad
- Round stainless steel weighing pan is removable and features
a wrap-around design
- Reliable overload protection, side impact protection * Raised
display unit, tiltable
- Backlit liquid-crystal display
- Conversion mode for other paint can sizes as a standard feature
- Standard data interface
-
Applications: batching, explosion proof weighing, unit toggle, net-total,
calculation
- External calibration
- RS-232 interface standard
- The PMA-series scales come with a non-hazardous power supply
(no options)
Sartorius
FC-series Explosion Proof Scales
Sartorius FC-series explosion proof scales are designed
for use in ISO-certified production. For weighing hazardous liquids,
solids or gases, the Sartorius line of explosion-proof scales can
satisfy most of your stringent requirements. Because the
scale is intrinsically safe there is no need for a bulky containment
housing for most installations. All FC Series are ruggedly
built with stainless steel platforms, strong cast aluminum housing
and IP-54 rated against spills.
Sartorius FC-series explosion proof scales feature
the built-in isoTEST function: at the touch of a key, the scale
calibrates and adjusts itself automatically using a built-in calibration
weight. The scale is ruggedly constructed, and thanks to the easy-to-understand
operator guidance features, ease of operation is assured. Sartorius
FC series scales also feature practical application programs and
menu-driven operator guidance. The scales also feature product
data memory and configuration options for customizing printouts.
Binary interface for controlling external devices is a standard
feature with Sartorius FC-series scales
The Sartorious explosion proof scales boast practical
application programs, and allow for complex tasking by combining
application programs. Display prompts are in plain English. Input
of manufacturing data is convenient: use the bar code scanner and/or
a PC keyboard. And the high-contrast display continuously shows
the maximum weighing capacity and the resolution. Look to Sartorius
FC-series explosion proof scales for precise, yet fast weighing
results. All Sartorius explosion proof scales come with a two year
factory warranty.
Sartorius FC-series Explosion Proof Scales are Family Mutual Approved for use
in Class 1, Division I, Groups A,B,C,D hazardous environments.
Note that the power supply all FC Series IS NOT INCLUDED
and you must purchase separately either the YPS02-ZKR Safe area
power supply or the YPS02-XKR Hazardous area power supply (requires
installation by a licensed electrician).
Sartorius FC-Series Features
- Weighing Modes: Carats, Grains, Milligrams, Pounds, Ounces,
Pennyweight, Grams, Troy Ounces, Kilograms
- Parts Counting feature
- Internal calibration
- RS232C interface
- isoTEST internal calibration
- IP54
- GMP/GLP printout
- Backlit LCD display
- Below balance weighing
Specifications
| Model |
Price |
Capacity x Readability |
Reproducibility (+/-) |
Linearity (+/-) |
Platform size |
Shipping Wt |
| FC06BBE-SX |
$4200 |
600 g x 0.001 g |
0.001 g |
0.002 g |
5.1"
diameter |
22 lbs |
| FC2CCE-SX |
$3475 |
2,200 g x 0.01 g |
0.01 g |
0.02 g |
8.6" x 7.9" |
24 lbs |
| FC6CCE-HX |
$3695 |
6,200 g x 0.01 g |
0.01 g |
0.02 g |
8.6" x 7.9" |
24 lbs |
| FC6CCE-SX |
$3475 |
6,200 g x 0.1 g |
0.05 g |
0.1 g |
8.6" x 7.9" |
24 lbs |
| FC12CCE-SX |
$3695 |
12,000 g x 0.1 g |
0.05 g |
0.2 g |
8.6" x 7.9" |
24 lbs |
| PMA7500X |
$2195 |
7500 g x 0.1 g |
0.1 g |
0.3 g |
9.1" diameter |
13 lbs |
| PMA7500D-X |
$3125 |
999.95 / 7500 g x 0.05 / 0.1 g |
0.1 g |
0.3 g |
9.1" diameter |
13 lbs |
| Options |
| YDS02-ZKR |
$985 |
Safe area power supply for FC-series (65 feet of intrinsically
safe cable) - 110V only |
13 lbs |
| YDS02-XKR |
$1425 |
Hazardous area power supply
for FC-series (8 feet of intrinsic cable x 8 feet of cable requiring hardwiring
by a licensed electrician) - 110V only |
13 lbs |
What is meant by "Intrinsically Safe"?
Through the use of special components, materials, ratings and
component layouts, all electric circuits and inter-connected cables
are designed so that
a) no spark or
b) thermal effect is capable of causing ignition under fault conditions.
Intrinsically safe equipment can be isolated by Zener barriers
from non-intrinsically-safe circuits for data transfer to the safe
area
Basic principles of intrinsic safety:
- Voltage limitation
- Current limitation
- Limitation of storable energy
Advantages of intrinsically safe protection
- Equipment can be calibrated and maintained without removing
power
- General purpose wiring methods can be used for connection to
power
- No safety permits are required since the area does not need
to be “shut down” for servicing
Classification of Hazardous Locations in the
United States
Class
- Class I - locations in
which hazardous concentrations of flammable gases or vapors
exist
- Class II - locations which
are hazardous due to the presence of combustible or electrically
conductive dust of fibers
Division
- Division 1 - present continuously,
intermittently or periodically during normal operating conditions
- Division 2 - not present
under normal operating conditions, but as a result of equipment
failure, breakdown of containers or abnormal operation of ventilating
equipment
Groups
- Group A - atmospheres containing
acetylene
- Group B - atmospheres containing
hydrogen, gases or vapors of equivalent hazard such as natural
gas
- Group C - atmospheres containing
ethyl ether vapors, ethylene or cyclopropane
- Group D - atmospheres containing
gasoline,hexane, naptha, benzine, butane, propane, alcohol,
acetone, benzol, lacquer solvent vapors or other natural gases
Available Accessories for the Sartorius Explosion Proof Series
| Model |
Description |
Price |
|
| YDP03-OCE |
Data Printer with statistics and time/date functions, included cable fits RS232 |
$750 |
|
| 6906918 |
Ink Ribbon (fits YDP03-OCE printer) |
$18 |
|
| 6906937 |
Printer Paper, large size (internal), package of 5 rolls (fits YDP03-OCE printer) |
$18 |
|
| 69Y03090 |
Paper , four rolls, heat sensitive for YDP04IS-0CEV120 |
$53 |
|
| 69Y03092 |
Labels, Self-adhesive for YDP04IS-0CEV120, 2 x 1 inch, 1135 qty |
$30 |
|
| 69Y03093 |
Labels, Self-adhesive for YDP04IS-0CEV120, 2 x 3 inch, 500 qty |
$31 |
|
| 69Y03094 |
Labels, Self-adhesive for YDP04IS-0CEV120, 2 x 4 inch, 380 qty |
$40 |
|
| YCC01-0016M3 |
Cable, for connecting Sartorius accessories to FC series scales, 9.8 foot, 12-pin round (mail) connector to 25 D-sub (female) connector |
$180 |
|
| 6971413 |
Power Supply, for YDP03-OCE |
$53 |
|
| YPS02-XKR |
Power Supply, hazardous area (8 ft of intrinsic cable x 8 ft of cable requiring handwiring by licensed electrician) |
$1425 |
|
| YPS02-ZKR |
Power Supply, safe area (65 ft of intrinsically safe cable) |
$985 |
|
| 609308-61 |
Safe Area Power Supply (supplied with scale), 65 ft of intrinsically safe cable |
$270 |
|
| 72US1010.3 |
Data Transfer Software Wedge for DOS and Windows. Includes 5 foot cable, fits RS232
Completely collects balance data and transfers it to any DOS/WIndows application program |
$285 |
|
| LD2 |
Locking Device, anti-theft |
$50 |
|
| IDAC-97 |
Digital-to-Analog Converter, 25 D-sub connector, 5 foot (fits RS232) |
$780 |
|
| QLC-97-EP |
Set Point Controller (standard four), 25 D-sub connector, 5 foot (YCC01-16M3 and YD102-Z or YD103-Z required) |
$940 |
|
| PMACOMKIT-2X |
Barrier Kit, 2-channel shunt diode, with cables, for PMA7500-X and PMA7500D-X |
$445 |
|
| YD102-Z |
Zener Barrier (4x data lines) |
$850 |
|
| YD103-Z |
Zener Barrier (4x data lines, 4x control lines) |
$1030 |
|
| YPE05-X |
Foot Switch |
$270 |
|
| YTE02-X |
T-Connector |
$485 |
|
| 6960EA01 |
Dust Cover, for Display |
$23 |
|
| 6960FB01 |
Dust Cover, for Base |
$40 |
|
| 6960LP03 |
Dust Cover, for Display |
$37 |
|
Sartorius YDP03-OCE Statistical Printer

Retail Price: $835 - Our Price - $750 |
The Sartorius YDP03-OCE data printer has a built-in real-time clock and statistics programs -- designed for Sartorius balances equipped with an RS-232 interface. Text and data are printed with up to 24 characters per line and the unit is equipped with a real-time clock. A high contrast LCD shows the date or time as well as the current transaction number and integrated rechargeable batteries with battery level indicator. The printer runs on the balance's power -- no separate power supply is necessary. Easy to change paper roll and ink ribbon cassette.
The Sartorius YDP03-OCE data printer meets the quality standards of the chemical and pharmaceutical industries in compliance with the requirements of GLP (Good Laboratory Practice) and GMP(Good manufacturing Practice).
In addition to recording individual weighing data the data printer can generate a statistical evaluation of weighing data. All values transferred from an on-line weighing instrument are stored. The following can be computed/printed out.
- Number of weighing operations
- Mean value
- Standard deviation
- Variation coefficient
- Minimum value/weight
- Maximum vale/weight
- Difference between the maximum and minimum value/weight
The Sartorius YDP03-OCE data printer is powered by the Sartorius Balance via the printer cable that is supplied with the YDP03-OCE data printer. Turning ON the Sartorius balance when the printer is connected will automatically turn ON the printer. The rechargeable batteries with be charging when printer is not in use, but the balance is turned ON. The Sartorius YDP03-OCE uses a standard paper roll 57.5 mm ±0.5mm with a maximum diameter of 65mm.
- Dimensions: 6.2 W x 9.1 H x 3.1 D inches (158 x 230 x 80 mm)
- Print Speed: 2.5 lines/second
- Characters per line: 24
- Operating Temperature: 0 to 40°C / 32 to 104 °F
- Power: Runs on the balance's power, no separate power supply necessary
- Equipped with printer interface cable for connecting the printer to the Sartorius balance, Black ink ribbon cassette installed in unit and 4 NiCd rechargeable batteries and 1 roll of paper.
|
|